Intel® Server Chassis R2312WTXXX

Specifications

  • Product Collection Intel® Server Chassis R2000WT Family
  • Code Name Products formerly Big Horn Peak
  • Launch Date Q1'15
  • Marketing Status Discontinued
  • Expected Discontinuance Q3'20
  • EOL Announce Friday, July 19, 2019
  • Last Order Sunday, July 5, 2020
  • Last Receipt Attributes Monday, October 5, 2020
  • Limited 3-year Warranty Yes
  • Extended Warranty Available for Purchase (Select Countries) Yes
  • Chassis Form Factor 2U, Spread Core Rack
  • Chassis Dimensions 16.93" x 27.95" x 3.44"
  • Target Market Cloud/Datacenter
  • Redundant Fans Yes
  • Redundant Power Supported Supported, requires additional power supply
  • Backplanes Included
  • Included Items (1) Airduct; (1) standard control panel board (FXXFPANEL); (1) front I/O panel assembly (front 1xVGA and 2x USB); (12) 3.5 inch hot-swap drive carriers (FXX35HSCAR); (1) 12Gb SAS backplane (F2U12X35S3HSBP); (1) I2C cable for backplane; (1) power cable to the backplane; (1) ODD/fixed SSDs power cable; (2) processor heatsinks (FXXCA84X106HS); (2) Riser Card mouting brackets supporting up to 3 riser cards (riser cards sold separately); (6) Hot swap system fans (FR2UFAN60HSW); (1) set chassis handles with Integrated control panel & USB Port (A2UHANDLKIT)

Supplemental Information

  • Description 2U server chassis designed for the Intel® Server Board S2600WT family supporting up to 12 3.5 inch hot-swap drives. Power supply, risers, and SAS cables sold separately
  • Additional Information View now

Memory & Storage

  • # of Front Drives Supported 12
  • Front Drive Form Factor Hot-swap 2.5" or 3.5"

Package Specifications

  • Max CPU Configuration 2

Compatible Products

Intel® Server Board S2600WT Family

Compare
All | None

Add-in Cards

Compare
All | None

Bezel Options

Product Name Launch Date Marketing Status Sort Order Compare
All | None
2U Bezel A2UBEZEL Q2'12 Discontinued 63262

Cable Options

Product Name Launch Date Marketing Status Sort Order Compare
All | None
1U/2U Cable Management Arm AXX1U2UCMA Q1'12 Launched 63283
Accessory DC Power Cable AXXDCCRPSCBL Q3 14 Launched 63294
Cable kit AXXCBL875HDHD Q3'14 Launched 63332
Cable kit AXXCBL950HDHD Q3'14 Launched 63337

Chassis Control Panel Options

Product Name Launch Date Marketing Status Sort Order Compare
All | None
Local Control Panel A1U2ULCP Q4'12 Discontinued 63452
Rack Handle Kit for R2000G Family A2UHANDLKIT Q4'14 Launched 63470

Drive Bay Options

Fan Options

Product Name Launch Date Marketing Status Sort Order Compare
All | None
Passive Airduct Kit AWTCOPRODUCT Q4'14 Discontinued 63567

Power Options

Product Name Launch Date Marketing Status Sort Order Compare
All | None
1100W AC Common Redundant Power Supply AXX1100PCRPS (Platinum Efficiency) Q3'14 Launched 63773

Rail Options

Compare
All | None

Riser Card Options

Product Name Launch Date Marketing Status Sort Order Compare
All | None
2U Spare Short Riser A2UX8X4RISER Q4'14 Launched 63910

Spare Chassis Control Panel Options

Product Name Launch Date Marketing Status Sort Order Compare
All | None
Front Panel Spare FXXFPANEL Q1'12 Discontinued 64210
Front Panel Board FXXFPANEL2 Q3'14 Launched 64211

Spare Drive Bays & Carrier Options

Compare
All | None

Spare Fan Options

Compare
All | None

Spare Heat-Sink Options

Compare
All | None

Spare Power Options

Product Name Launch Date Marketing Status Sort Order Compare
All | None
North America Power cable FPWRCABLENA Q2'06 Launched 64596

Spare Riser Card Options

Product Name Launch Date Marketing Status Sort Order Compare
All | None
2U Riser Spare A2UL16RISER2 (2 Slot) Q4'14 Launched 64665
2U Riser Spare A2UL8RISER2 (3 Slot) Q4'14 Launched 64668

Drivers and Software

Latest Drivers & Software

Downloads Available:
All

Name

Support

Launch Date

The date the product was first introduced.

Expected Discontinuance

Expected Discontinuance is an estimate of when a product will begin the Product Discontinuance process. The Product Discontinuance Notification (PDN), published at the start of the discontinuance process, will include all EOL Key Milestone details. Some business units may communicate EOL timeline details before the PDN is published. Contact your Intel representative for information on EOL timelines and extended life options.